Telecrane Industrial Remote Controls – Program Copier
Program Copier
The copier unit is a Telecrane Taiwan original device that gets the product information from the transmitter or receiver unit and synchronize them into another device.
Three buttons are available on the copier, and each button is capable of storing one set of data at a time and the previously saved data will be erased automatically once new data is stored.
“COPIER” copy procedure.
To copy data from Rx unit to Tx unit
- Turn off all power to RX, and remove batteries from TX, leave without power for at least 10 seconds.
- Place green magnet in copier for “read” function.
- Plug copier lead into RX program socket.
- * Depress buttons #’s 1, 2 or 3 ( any one button is suitable, but you must remember which numbered button is used ).*
- When flashing LED turns green, release button and wait for 30 seconds.
- Remove copier lead from RX unit.
- Remove green magnet from copier for “write” function.
- Plug copier lead into program socket in RX.
- Depress same button as used to “read” from TX.
- When flashing LED turns green, release button and wait for 30 seconds.
- Remove copier lead from RX.
- Re-apply normal operational power to RX.
- Replace cover and batteries to TX.
- Depress/turn and hold start push button/switch on TX, hold in “START” position for 5 seconds.
- Test Unit.
Similar procedure to be followed to copy data from Tx Unit to Tx Unit, Rx Unit to Rx Unit.
Use of copier for copy data from Tx Unit to Rx Unit is not recommended.